Basit öğe kaydını göster

dc.contributor.advisorErbek, Selim Sermed
dc.contributor.authorDemir, Serpil
dc.date.accessioned2017-05-09T11:16:05Z
dc.date.available2017-05-09T11:16:05Z
dc.date.issued2016
dc.identifier.urihttp://hdl.handle.net/11727/2511
dc.description.abstractRomatoid artrit (RA), CD4 (+) T hücreleri ve monositlerin, damardan inflamasyonlu sinoviyal dokuya ve sinoviyal sıvıya geçmesiyle karakterize, otoimmün bir hastalıktır. Çalışmamızın amacı; Romatoid artrit hastalarında orta kulak, iç kulak ve eferent işitme sistemini, multifrekans timpanometri, geçici uyarılmış otoakustik emisyon (TEOAE) ve kontralateral supresyon testi ile detaylı olarak incelemektir. Çalışmaya 35 romatoid artrit hastası ve 40 sağlıklı birey olmak üzere toplam 75 kişi dahil edilmiştir. Katılımcıların immitansmetrik ölçümleri yapıldıktan sonra saf ses odyometri ile işitme eşikleri ölçülmüştür. Daha sonra her iki grubun geçici uyarılmış otoakustik emisyon testiyle değerlendirmesi: kontrolateral akustik stimülasyon (KAS) verilmeden önce ve 70 dB dar band KAS verilirken olacak şekilde iki aşamalı olarak ölçülmüştür. Romatoid artrit hastalarının yaş ortalaması 44,31±10,4, Kontrol grubunun yaş ortalaması 41,48±12,5 olup fark istatistiksel olarak anlamlı bulunmadı (p=0,293). 125Hz-16000 Hz frekansları arasında romatoid artrit ve kontrol grubu saf ses işitme eşikleri karşılaştırıldığında, bütün frekanslarda romatoid artrit hastalarının saf ses işitme eşikleri daha yüksek olarak bulundu. Bu fark, sağ kulakta 2000 Hz, 14000 Hz ve 16000 Hz, sol kulakta 16000 Hz frekansları haricinde tüm frekanslarda istatistiksel olarak anlamlı bulundu (p<0,05). Bireylerin tamamında timpanogram sonuçları normal sınırlarda bulundu. Multifrekans timponometri testinde hasta ve kontrol grubunun sağ kulak rezonans frekansları değerleri sırasıyla 748,86 ± 188,06; 830,00 ± 122,37, sol kulak değerleri sırasıyla 772,86 ±157,80; 847,50 ± 140,94 Hz bulundu. Fark istatistiksel açıdan anlamlı idi (p<0,05). Otoakustik emisyon testiyle yapılan değerlendirmede, iki grup TEOAE sonuçları karşılaştırıldığında romatoid artritli hastalardan alınan emisyon yanıtları kontrol grubuna göre 1000 Hz, 2000 Hz, 2800 Hz, 4000Hz frekanslarında istatistiksel olarak anlamlı düşüş saptandı. (p<0,05). Kontralateral supresyon seviyelerini değerlendirmek amacıyla, kontralateral akustik uyaran (KAS) verilmeden ve KAS verilirken yapılan TEOAE ölçümleri karşılaştırıldığında; hasta grubunda 2800 ve 4000 Hz frekansları dışında, kontrol grubunda tüm frekanslarda emisyon değerlerinde istatistiksel olarak anlamlı düşüş saptandı (p<0,001). Her iki gruptaki kontralateral supresyon seviyeleri (dB) karşılaştırıldığında ise fark istatistiksel olarak anlamlı değildi (p>0,05). Sonuç olarak elde ettiğimiz bulgular, romatoid artrit hastalığında işitsel disfonksiyon varlığını göstermektedir. Romatoid artrit tanısı konulduğunda hastaların odyolojik değerlendirmesi de yapılmalı ve hastalar olası otolojik tutulum hakkında bilgilendirilmelidir. Romatoid artrit hastalarında orta ve iç kulak fonksiyonlarının etkilenimi ve bu olası etkilenimler ile ilişkili olabilecek hastalık özelliklerine yönelik çalışmalara devam edilmelidir. Rheumatoid arthritis (RA) is an autoimmune disease which is characterized by the passage of primarily CD4 (+) T cells and monocytes into the intravenous inflamed synovial tissue and synovial fluid. The aim of our work was to examine middle ear, inner ear and efferent auditory system by using multifrequency tympanometry, transient evoked otoacoustic emission (TEOAE) and contralateral suppression test in detail. A total of 75 subjects; 35 patients with rheumatoid arthritis and 40 healthy subjects participated in the study. Immitansmetric measurements of participants were performed, and then their hearing levels were measured applying pure tone audiometry. The evaluation of each group with otoacoustic emission test was performed in two stages: before giving contralateral acoustic stimulation (CAS) and during 70 dB narrow band contralateral acoustic stimulation. Mean age of patients with rheumatoid arthritis was 44,31±10,4, mean age of control group was 41,48±12,5 and the difference between groups was not statistically significant (p=0,293). By comparison pure tone hearing levels between rheumatoid arthritis and control group at 125Hz-16000 Hz frequency, pure tone hearing levels of rheumatoid arthritis patients at all frequencies were higher. These differences were found statistically significant except for 2000 Hz, 14000 Hz and 16000 Hz in right ear, 16000 Hz in left ear (p<0,05). Tympanogram results in all of the subjects were within normal limits. The value of the resonant frequency of the patient and control group were respectively for right ear 748,86 ± 188,06 ; 830,00 ± 122,37, for left ear 772,86 ±157,80; 847,50 ± 140,94 Hz. The difference was statistically significant (p<0,05). When compared two groups‟ TEOAE results, emission results obtained from rheumatoid arthritis patients were statistically significantly lower than control group at 1000Hz, 2000Hz, 2800Hz and 4000Hz frequencies (p<0,05). When TEOAE measurement before and during contralateral acoustic stimulation (CAS) were compared to evaluate the contralateral suppression level, it was detected that there was decline in emission values except for 2800 and 4000 Hz at all frequencies in study group and there was decline in emissions values all frequencies control group (p<0,001).There was no statistically significant difference between contralateral suppression levels in both groups (p>0,05). As a result, our findings indicate the presence of auditory dysfunction in rheumatoid arthritis. When the rheumatoid arthritis is diagnosed, the patients should be undergo audiologic evaluation and informed about possible pathological involvement. Future studies should continue about middle and inner ear condition in rheumatoid arthritis patients and potential interactions that may be associated with disease characteristics.en_US
dc.language.isoturen_US
dc.publisherBaşkent Üniversitesi Sağlık Bilimler Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectRomatoid artriten_US
dc.subjectOdyometrien_US
dc.subjectGeçici uyarılmış otoakustik emisyon (TEOAE)en_US
dc.subjectMultifrekans timpanometrien_US
dc.titleRomatid artrit hastalarında orta ve iç kulak fonksiyonlarının değerlendirilmesien_US
dc.typemasterThesisen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster