Show simple item record

dc.contributor.authorInce-Bingol, Sinem
dc.contributor.authorKaya, Burcak
dc.contributor.authorBayram, Burak
dc.contributor.authorArman-Ozcirpici, Ayca
dc.date.accessioned2021-05-31T07:51:41Z
dc.date.available2021-05-31T07:51:41Z
dc.date.issued2020
dc.identifier.issn1432-6981en_US
dc.identifier.urihttp://hdl.handle.net/11727/5934
dc.description.abstractObjectives The aim of the study was to investigate the treatment efficiency of miniplate anchored Forsus Fatigue Resistant Device (MAF) as compared with the activator appliance. Materials and methods Mandibular retrognathia was treated with two methods, the MAF group (8 girls, 11 boys, mean age 13.03 +/- 0.69 years) and the activator group (7 girls, 12 boys, mean age 12.68 +/- 0.73 years). An untreated control group (9 girls, 10 boys, mean age 12.95 +/- 0.73 years) was constructed to eliminate growth-related changes through the American Association of Orthodontists Foundation Legacy Collection. Data of 114 lateral cephalograms were analyzed. Results The inhibition of the maxillary growth was greater in the MAF group, whereas forward displacement of the mandible was higher in the activator group (P < 0.05). Sagittal maxillomandibular relation was improved similarly in both treatment groups (P < 0.05). Mandibular length was increased in both treatment groups with the highest increase in the activator group (P < 0.05). Retroclination of the incisors was observed in the MAF group (P < 0.05). The upper lip was retruded in the MAF group and lower lip was protruded in the activator group (P < 0.05). Conclusion The activator created greater mandibular changes, whereas the MAF provides somewhat smaller mandibular changes due to the restriction caused by retroclined maxillary incisorsen_US
dc.language.isoengen_US
dc.relation.isversionof10.1007/s00784-020-03458-3en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectActivator applianceen_US
dc.subjectClass II malocclusionen_US
dc.subjectFixed functional appliancesen_US
dc.subjectMandibular advancementen_US
dc.subjectSkeletal anchorageen_US
dc.titleTreatment efficiency of activator and skeletal anchored Forsus Fatigue Resistant Device appliancesen_US
dc.typearticleen_US
dc.relation.journalCLINICAL ORAL INVESTIGATIONSen_US
dc.identifier.volume25en_US
dc.identifier.issue3en_US
dc.identifier.startpage1505en_US
dc.identifier.endpage1512en_US
dc.identifier.wos000548767300001en_US
dc.identifier.scopus2-s2.0-85087962532en_US
dc.contributor.pubmedID32671559en_US
dc.contributor.orcID0000-0002-7014-0784en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergien_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record