Comparison of Keratometric Measurements Obtained by the Verion Image Guided System with Optical Biometry and Auto-Keratorefractometer
(2017)
The aim of this study was to compare the keratometric measurements of Verion Image Guided System with an optical biometer (Zeiss IOLMaster 500, Carl Zeiss Meditec, Jena, Germany) and an automated keratorefractometer (AKR) ...
Non-Contact and Contact Tonometry in Corneal Edema
(2016)
Purpose To compare the intraocular pressure (IOP) values by Goldmann applanation tonometry (GAT) and Reichert 7 CR noncontact tonometry (R7CR-NCT) in patients with postsurgical corneal edema and to examine the impact of ...
Comparison of Keratometry Obtained by a Swept Source OCT-Based Biometer with a Standard Optical Biometer and Scheimpflug Imaging
(2018)
Purpose: To assess agreement of a swept source-optical coherence tomography (SS-OCT) based Biometer with a standard IOLMaster device and Scheimpflug Imaging (SI) to acquire keratometric measurements in cataract ...
Circumferential Ciliary Body Cysts Presenting as Acute Pigment Dispersion and Ocular Hypertension
(2018)
Purpose: To report a case of circumferential neuroepithelial cyst of the ciliary body presenting with pigment dispersion (PD) and ocular hypertension. Case report: 48-year-old female patient presented with a complaint of ...
Comparison of The Mechanical Properties of The Anterior Lens Capsule in Senile Cataract, Senile Cataract with Trypan Blue Application, and Pseudoexfoliation Syndrome
(2017)
Purpose: To evaluate the elastic modulus, hardness, and mechanical properties of the anterior lens capsule in different types of cataract and to assess the correlation with age.
Setting: Baskent University Hospital, ...
Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
(2015)
Purpose:The aim of this study was to compare the Reichert 7 (R7) noncontact tonometry with Goldmann applanation tonometry (GAT) and to determine the influence of central corneal thickness (CCT) in these measurements in the ...
Atypical Intrapapillary Hemorrhage in a Patient with Glaucoma
(2015)
A 73-year-old man presented for routine follow-up. There were primary open-angle glaucoma, diabetes mellitus, and usage of acetylsalicylic acid in patient's history. Dilated fundus examination demonstrated cup hemorrhage ...
Clear Lens Phacoemulsification in Alport Syndrome: Refractive Results and Electron Microscopic Analysis of The Anterior Lens Capsule
(2014)
Purpose: To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group.
Methods: Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were ...
Evaluation of quality of life after implantation of a new trifocal intraocular lens
(2019)
Purpose: To evaluate the vision-related quality of life (QOL) after implantation of a new trifocal intraocular lens (IOL), by using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire).
Setting: ...